Home>Free BS Standards>BS EN 14187-9 pdf free download

BS EN 14187-9 pdf free download

BS EN 14187-9-2019 pdf free download.Cold applied joint sealants – Test methods Part 9: Function testing of joint sealants.
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 6927:2012 apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.orgJobp
4 Principle
This method describes an accelerated test for the assessment of damage of the cold applied sealants arising from the influence of fluctuating temperatures, water-spraying and simultaneous dynamic load.
5 Apparatus and materials
5.1 Concrete test blocks
Concrete supports in accordance with EN 13880-12. for the preparation of the test specimens, of dimensions as shown in Figure 1. Two supports are required for each test specimen.
5.2 Tensile/compression test rig
Apparatus which allows specimens to be inserted into holding clamps, conveniently and without disturbing the specimens before, during or after removal shall be used. The apparatus shall be capable of testing a number of test specimens simultaneously and shall not be significantly affected by the failure of one or more specimens.
The apparatus shall have the following characteristics:
— be motor driven through positive drives without slip or significant backlash, so that cycles of extension and compression are carried out steadily and automatically;
— be capable of moving the test blocks and specimens smoothly and linearly, so that their alignment is maintained at all times without subjecting them to torsion, bending, shock, or significant vibration;
— be capable of exerting on each specimen an appropriate tensile/compression force and extending the specimen uniformly under the specified conditions according to 72 and 7.4;
— be capable of measuring and recording the force with an uncertainty of maximum 2 % after application of the force to each system;
— the tolerance of the movement shall not exceed 0,01 mm.
5.3 Climate chamber
Climate chamber shall be capable of reducing the temperature of the specimens to the specified temperature in the range from —30°C to 30°C drop/rise throughout the period of examination.
The chamber shall be fitted with a time controlled device to allow the specimen to be subjected to spraying with distilled or demineralized water for 20 % of the total conditioning time at the fixed temperatures as provided in 7.4.
5.4 Temperature indicator
The temperature indicator shall consist of an electronic device capable of measuring temperatures in the range of -40 °C to 50 °C to an accuracy of ii °C.
6 Preparation of the test specimens
For each test, at least three test specimens shall be prepared.
Prepare the test specimens in accordance with the manufacturer’s instructions including the application of a primer. etc. where stipulated. The test specimens shall be as shown in Figurel.
Prior to conditioning, the gelation time of the sealant shall be determined in the following way. Measure tack free time In accordance with EN 14187-2. Thereafter, prepare test specimens In accordance with EN ISO 7390.
After the preparation, place test specimens in standard conditions ((23 ± 2) °C, (50 ± 5) % r. h.).
Examine the first test specimen as described in EN ISO 7390, procedure B after the time equal to the tack free time. If no flow is observed, the gelation time is equal to the tack free time. In other cases, the examination shall be repeated in steps of additional 10 % of the tack free time until no flow is observed.
Prepare the test specimens and immediately after the sealant has gelled carefully mount them in the tensile test rig.BS EN 14187-9 pdf download.